A. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).

Clearance to combustible material under the insert is 1/4
inch (6 mm). Clearance to sides of fi replace opening to
combustibles is 6 inches (152 mm). Clearance from top of
fi replace opening (152 mm) to combustibles extending 1
inch is 6 inches. Clearance from top of fi replace opening
for combustibles extending 1 inch to 12 inches max. is 12
inches. See Figure 11.1.

• Use leveling legs to raise insert minimum 1/4 inch (6 mm)

above combustible material or outer wrap of factory built
fi rebox.

Combustible facings must not extend behind the insert
surround.

11

11

Finishing

Note: All
measurements
in inches.

MEASUREMENTS FROM

TOP EDGE OF UNIT

12 in. MIN.

12 in. MAX.

MANTEL

EXHAUST

VENT PIPE

INLET AIR

VENT PIPE

Figure 11.1 Clearances to Mantels or other Combustibles
above

Appliance