Castile Pellet Insert
1
.
A 12 volt AC thermostat is required to operate this 
pellet appliance. You may use the included wall mount 
thermostat or purchase an optional programmable 
thermostat or remote control. The included thermostat 
is equipped with an adjustable heat anticipator. The 
current rating is .05 amps. The anticipator needs to 
be adjusted to the lowest setting available.
2.
When mounting a thermostat on a wall, be sure to follow 
your thermostat installation instructions carefully.
NOTE: Thermostat must be mounted level for accu-
rate readings. The thermostat should be mounted 
on an inside wall and not in direct line with the 
appliance convection air. Remove any packaging 
from inside the thermostat before using.
NOTE: If the thermostat is located too close to 
the appliance, you may need to set the tempera-
ture setting slightly higher to maintain the desired 
temperature in your home.
3.
There is a 4 screw terminal block located on the junc-
tion box to the left of the power cord inlet. The center 
2 screws are for the thermostat wires. The outer 2 are 
the mounting screws for the terminal block. Figure 
23.1.
H. Thermostat Installation
Figure 23.1
Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong 
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appli-
ance.
CAUTION
Control Box
Junction Box
Reset Button
Heat Output 
Switch
Power Cord
Outlet
Thermostat
Block
Fuse
Red Call
Light
Red/
Gre
en/A
mbe
r Light
Blu
e Light