Caution, Castile pellet insert, H. thermostat installation – Quadra-Fire CASTINS-CSB User Manual

Page 23

Advertising
background image

R

August 20, 2009

250-7251G

Page 23

Castile Pellet Insert

1

.

A 12 volt AC thermostat is required to operate this
pellet appliance. You may use the included wall mount
thermostat or purchase an optional programmable
thermostat or remote control. The included thermostat
is equipped with an adjustable heat anticipator. The
current rating is .05 amps. The anticipator needs to
be adjusted to the lowest setting available.

2.

When mounting a thermostat on a wall, be sure to follow
your thermostat installation instructions carefully.

NOTE: Thermostat must be mounted level for accu-
rate readings. The thermostat should be mounted
on an inside wall and not in direct line with the
appliance convection air. Remove any packaging
from inside the thermostat before using.

NOTE: If the thermostat is located too close to
the appliance, you may need to set the tempera-
ture setting slightly higher to maintain the desired
temperature in your home.

3.

There is a 4 screw terminal block located on the junc-
tion box to the left of the power cord inlet. The center
2 screws are for the thermostat wires. The outer 2 are
the mounting screws for the terminal block. Figure
23.1.

H. Thermostat Installation

Figure 23.1

Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong

receptacle.

• Route cord away from appliance.
• Do NOT route cord under or in front of appli-

ance.

CAUTION

Control Box

Junction Box

Reset Button

Heat Output
Switch

Power Cord
Outlet

Thermostat
Block

Fuse

Red Call
Light

Red/

Gre

en/A

mbe

r Light

Blu

e Light

Advertising