Castile Pellet Insert

The fuel adjustment control rod is factory set, and should be
adequate for most fuels.

The set screw is located at the bottom of the hopper and
set loose at the factory so the fuel adjustment control rod
will slide by only loosening the wing nut. Do not re-tighten
bottom set screw.

However, if the flame height is too high or too low, you will
need to adjust the feed rate. Wait until the appliance has been
burning for 15 minutes before making your adjustments and
allow 15 minutes for feed adjustment to take effect. Make
adjustments in approximately 1/2 inch increments.

1. Loosen the wing nut. Figure 26.1.

2. Adjust the fuel adjustment control rod towards the
"+" symbol to increase the feed rate and fl ame height or
towards the "-" symbol, to decrease the feed rate and fl ame
height.

3. Re-tighten the wing nut.

F. Feed Rate Adjustment

Figure 26.1

Control Box

Junction Box

Reset Button

Heat Output
Switch

Power Cord
Outlet

Thermostat
Block

Fuse

Red Call
Light

Red/Green Light

Blue Light

Wing Nut

"+"

"-"

G. Iginition Cycles

1. During each ignition cycle, it is normal to see some smoke

in the fi rebox. The smoke will stop once the fi re starts.

2. The convection blower will automatically turn on after your

appliance has reached the set temperature. This blower
transfers heat from your appliance into the room, and will
continue to run after the thermostat has stopped calling
for heat until the appliance has cooled down.

3. Occasionally the appliance may run out of fuel and shut

itself down. When this happens, the red call light will
be on. To restart it, fi ll the hopper and press the reset
button. Figure 26.2. When you press the reset button
the red call light will go out. Release the button and the
light will come back on. You should see a fi re shortly.
If not, follow the instructions on page 25, “Starting Your
First Fire”.

WARNING

Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Firepot fl oor open.
• Cleaning slide plates open.
Do NOT store fuel:
• Closer than required clearances to com-

bustibles to appliance

• Within space required for loading or ash

removal.

Back side of Firepot

Firepot floor left open

Figure 26.2 - DO NOT LEAVE FIREPOT FLOOR OPEN