Castile Pellet Insert

10

Maintaining & Servicing Your Appliance

C. General Maintenance & Cleaning

1. Types of Fuel

Depending on the type of fuel you are burning will dictate how
often you have to clean your fi repot.

If the fuel you are burning has a high dirt or ash content or
you are burning shelled fi eld corn, it may be necessary to
clean the fi repot more than once a day.

Dirty fuel will cause clinkers to form in the fi repot. A clinker
is formed when dirt, ash or a non-burnable substance is
heated to 2000°F (1093°C) and becomes glass-like. See
D” page 35 in this section for more details on fuels with
high ash content.

Clinker

Figure 31.1 - Clinker

Shock and Smoke Hazard

• Turn down thermostat, let appliance completely

cool and exhaust blower must be off. Now you
can unplug appliance before servicing.

• Smoke spillage into room can occur if appliance

is not cool before unplugging.

• Risk of shock if appliance not unplugged before

servicing appliance.

CAUTION

A. Proper Shutdown Procedure

Cleaning or Inspection

Frequency

Daily Weekly Monthly

Yearly

Ash Pan

Every 5 bags of fuel

OR

X

Ash Removal from Firebox

More frequently depending on
the fuel type or ash build-up

OR

X

Beneath Heat Exchanger

Every 1 ton of fuel

OR

X

Blower, Combustion (Exhaust)

More frequently depending on
the fuel type

OR

X

Blower, Convection

More frequently depending on
the fuel type

OR

X

Door Latch Inspection

Prior to heating season

OR

X

Exhaust Path

More frequently depending on
ash build-up

OR

X

Firebox - Prepare for Non-Burn Season

At end of heating season

OR

X

Firepot - Burning pellets - hardwood

Every 3 bags

OR

X

Firepot - Burning pellets - softwood

Every 5 bags

OR

X

Firepot - Burning Corn

Every 1 bag

OR

X

Glass

When clear view of fi repot
becomes obscure

OR

X

Heat Exchanger & Drop Tube

Every 1 ton of fuel

OR

X

Hopper

Every 1 ton of fuel or when
changing fuel types

OR

X

Top Vent Adapter

More frequently depending on
the fuel type or ash build-up

OR

X

Venting System

More frequently depending on
the fuel type

OR

X

B. Quick Reference Maintenance Chart

Follow the detailed instructions found in this
section for each step listed as referenced in the
chart below
.

NOTICE: These are recommendations. Clean more frequently if you encounter heavy build-up of

ash at the recommended interval or you see soot coming from the vent. Not properly