16. Snap Disc #1 (Convection Blower) 110°F
Snap disc #1 is located behind the right cast side of the fi rebox 
above the red call light. There are 2 purple wires connected 
to it. This snap disc turns the convection blower on and off as 
needed. Power is always present at snap disc #1.
17. Snap Disc #2 (Fuel Delivery Interrupt) 250°F
Snap disc #2 is located on the back side of the feed drop 
tube. There is 1 orange wire and 1 black wire connected to 
it. This snap disc will turn off the feed system, which will turn 
off the appliance if an overfi re condition should occur or if the 
convection blower should fail to operate. If this occurs the 
snap disc with automatically reset itself.
18. Snap Disc #3 (Burn Back Protector) 250°F
Snap disc #3 is mounted on the back of the auger tube in the 
center of the appliance and has a reset button. To access 
it remove the right cast side. If the fi re tries to burn back 
into the feed system or push exhaust up the feed tube, this 
snap disc will shut the entire system off. This disc must be 
manually reset.
Thermocouple
Burn
Selector
Thermostat
Block
Female
Male
Igniter
Call
Light
Snap
Disc #3
Reset
Button
Fuse
Receptacle
Snap
Disc #1
Exhaust
Blower
Convection
Blower
Vacuum
Switch
Snap
Disc #2
Capacitor
Feed
Motor
Yellow
Y
ellow
Y
ellow
Blue
Blue
Gray
Gray
Black
Black
Black
Black
Black
White
White
Red
Red
Purple
Red
White
19. Vacuum Switch
The vacuum switch is located at the back of the appliance. 
This switch turns the feed system on when vacuum is present 
in the fi rebox. The vacuum switch is a safety device to shut 
off the feed motor if the exhaust or the heat exchanger 
system is dirty or plugged or if the fi rebox door is open. 
20. Wiring Harness
See Figure 40.1 below
Figure 40.1