DEFROST TIME CLOCK OPERATION

Instructions for TAC-48, TAC-48GS, and TAC-72RC models.

RECOMMENDED DEFROST
SETTINGS:
TRUE Manufacturing has factory

set your defrost time clock to a

recommended time and duration defrost

scenario. Your TRUE equipment has

been designed for three defrost periods

(6:00 a.m., 2:00 p.m. and 10:00 p.m.). If

you decide to deviate from these defrost

time settings please follow the procedures

for adjustment below.

NOTE:
Defrost timer will need to be set at current

time of day before plugging unit into power

supply. The defrost times have been set

from the factory. If you want to change

defrost times please read through the

defrost timer instructions.

REQUIRED TOOLS:
• Phillips Screwdriver

• 1/4” Nut Driver or Socket

TAC Defrost Timer Location:
Defrost timer is located in a ballast box

behind the front louvered grill on the left

side of the unit. Four corner screws on

the front louvered grill will need to be

removed. The ballast box has two 1/4”

hex head screws that need to be removed

to gain access to the defrost control.

Setting the timer:
(UNPLUG UNIT FROM
POWER SUPPLY!)

DO NOT SET THE TIME BY
ROTATING THE “OUTER” DIAL.
Turn the minute hand clockwise until the

time of day on the outer dial is aligned

with the triangle marker on the inner dial

(two o’clock position).

Adjusting The Defrost Timer:
(time initiated, time terminated)

Your TRUE equipment contains a defrost

system that is time initiated and time

terminated. While TRUE requires a

minimum 3 defrost periods not to exceed

30 minutes the procedure on this page

should be followed to customize your

specific needs.

Notice
If timer is not set for a minimum of 3

defrost per day for 30 minutes each, the

coil may develop excessive frost. This may

lead to system failure and product loss,

which is not covered under warranty.

The following procedure may be followed

to customize your needs.

High usage, high temperature, and high

humidity may require 4 defrost settings

per day.

WARNING

Always follow the

manufacturer’s recommended settings

when programming the amount and

duration of the

defrost cycles.

Defrost Timer Image 2

STEP 1
The white tabs located on the outmost

area of the time clock have been factory

set for (6:00 a.m., 2:00 p.m., and 10:00

p.m.). Each tab represents 15 minutes

of defrost time. Notice that at each

defrost time two white tabs are set for 15

minutes each for a total of 30 minutes of

defrost.

STEP 2
In order to program the time to begin the

defrost cycle, flip the white tabs out to set

the defrost time. To eliminate a defrost

time flip the white tabs back toward the

center of the Defrost Timer.

STEP 3
TRUE recommends a 30 minute defrost

cycle three times per day.

Defrost Timer Box Image 1

Outer most dial. White tabs represent 15
minutes of defrost time.

Time of day.

Inner most dial.