How to change the “set point, Lae electronic control, May need to unlock control – True Manufacturing Company TAC-36 User Manual

Page 21: True food service equipment, inc

Advertising
background image

............ www.truemfg.com ............

True Food Service Equipment, Inc.

19

19

LAE Electronic Control

Info/Set Point

Button

Manual Defrost/

Down Button

Manual Activation/

Up Button

Stand-By

Button

1

2

Compressor

Running

Activation of 2nd

Parameter Set - NA

Alarm - NA

Cabinet in Defrost

Evaporator Fan

Running

LAE Control Icons

May need to unlock control.

WHY:
THE SET POINT IS THE TEMPERATURE AT WHICH THE

COMPRESSOR WILL SHUT OFF.
Please note that the “set point” IS NOT the cabinet

holding temperature.

HOW:
A.
To see the set point, press and hold the info button.

See image 1.

B. While still holding the info button ,

press the up or down button to change

the “set point”.

C. Once the “set point” has been set correctly release the

info button .

The display will show temperature. See image 2.

HOW TO CHANGE THE “SET POINT”

Advertising
This manual is related to the following products: