How to change “defrost intervals, 12 3 4 lae electronic control, May need to unlock control – True Manufacturing Company TAC-36 User Manual

Page 23

Advertising
background image

............ www.truemfg.com ............

True Food Service Equipment, Inc.

21

21

1

2

3

4

LAE Electronic Control

Info/Set Point

Button

Manual Defrost/

Down Button

Manual Activation/

Up Button

Stand-By

Button

Compressor

Running

Activation of 2nd

Parameter Set - NA

Alarm - NA

Cabinet in Defrost

Evaporator Fan

Running

LAE Control Icons

WHY:
THE DEFROST INTERVAL IS THE TIME DURATION BETWEEN

DEFROST CYCLES.
The Defrost Interval time starts when the cabinet is supplied

power or after a manual defrost.

HOW:
A.
To see the set point, press and hold the info button

and the stand-by button at the same time.

“ScL” will appear. See image 1.

B. Push the up button until “dFt” appears.

See image 2.

C. Press and hold the info button to see the

“defrost interval time”. See image 3.

D. While pressing and holding the info button ,

press the up or down button to change the “defrost

interval times” (higher the number the less frequent the

cabinet will defrost).

E. Once the “defrost interval time” has been changed,

release the info button .

Wait 30 seconds for the display to show temperature.

See image 4.

HOW TO CHANGE “DEFROST

INTERVALS”

May need to unlock control.

This can only be changed if defrost mode parameter “DFM” is set for “TIM”.

Advertising