INSTALLATION / OPERATION INSTRUCTIONS

Leg levelers in the bottom of the cabinet
can be backed out for leveling.

Leg Levelers:
If the cabinet is not level use an open-end wrench and turn

adjustable tips on legs until cooler is level. (See image 1).
Castor Installation: (Kit Contents)
2 - Castor mounting bracket
2 - Castor, 2-1/2” diameter wheel with 3/8” - 16 x 1-

1/2” threaded stem without brake
2 - Castor, 2-1/2” diameter wheel with 3/8” - 16 x 1-

1/2” threaded stem with brake

4 - Washer, flat, 3/8” I.D. x 1” O.D.
4 - Washer, split lock, 3/8” I.D.
4 - Nut, hex, 3/8” - 16
(See image 2).

CAUTION

To avoid damage to lower rail assembly, slowly raise unit to

upright position after installing castors.

2

A. Before your new unit is connected to a power supply,

check the incoming voltage with a voltmeter. If

anything less than 100% of the rated voltage for

operation is noted, correct immediately.

B. All units are equipped with a service cord, and must

be powered at proper operating voltage at all times.

Refer to cabinet data plate for this voltage.

TRUE requires that a sole circuit be dedicated for the unit.

Failure to do so voids warranty.
WARNING

Compressor warranties are void if compressor burns out due

to low voltage.

WARNING

Power supply cord ground should not be removed!
WARNING

Do not use electrical appliances inside the food storage

compartments of the appliances unless they are of the

type recommended by the manufacturer.

NOTE

To reference wiring diagram - Remove lower rear grill. Wiring

diagram is positioned on the inside cabinet wall.

ELECTRICAL INSTRUCTIONS

LEVELING

Securing Castors
A.
Set unit in its final location. Be sure there is adequate

ventilation in your room. Under extreme heat

conditions, you may want to install an exhaust fan.

WARNING

Warranty is void if ventilation is insufficient.
B.
Proper leveling of your TRUE cooler is critical to

operating success (for non-mobile models). Effective

condensate removal and door operation will be

effected by leveling.

C. The cooler should be leveled inside the cabinet front

to back and side to side with a level.

D. Ensure that the drain hose or hoses are positioned in

the pan.

E. Free plug and cord from inside the lower rear

of the cooler (do not plug in).

F. The unit should be placed close enough to the

electrical supply so that extension cords are never

used.

WARNING
Cabinet warranties are void if OEM power cord is tampered
with. TRUE will not warranty any units that are connected to an
extension cord.