Profibus parameter (pnu) – Toshiba Tosvert VF-MB1/S15 User Manual

Page 18

Advertising
background image

E6581738

- 16 -

3.6.

PROFIBUS parameter (PNU)

PNU R/W

data

type

Note

915 R

Array

[6]

Unsigned16

PNU 915, IND 0 = the

drive

parameter

c001

PNU 915, IND 1 = the

drive

parameter

c002

PNU 915, IND 2 = the

drive

parameter

c003

PNU 915, IND 3 = the

drive

parameter

c004

PNU 915, IND 4 = the

drive

parameter

c005

PNU 915, IND 5 = the

drive

parameter

c006

916 R

Array

[6]

Unsigned16

PNU 916, IND 0 = the

drive

parameter

c021

PNU 916, IND 1 = the

drive

parameter

c022

PNU 916, IND 2 = the

drive

parameter

c023

PNU 916, IND 3 = the

drive

parameter

c024

PNU 916, IND 4 = the

drive

parameter

c025

PNU 916, IND 5 = the

drive

parameter

c026

918 R

Unsigned16

Station

address monitor (same as the

drive

parameter c150).

922 R

Unsigned16

Telegram

selection

1, 100, 101, 102

927 R/W

Unsigned16

Operator

control rights (parameter identification, PKW).

Value

: Mode

0

:

Parameters cannot be written, only read

(927 can be written).

1: Parameters can be written and read (default).

928

R

Unsigned16

Control rights (process data, PZD).

1: PZD part is enabled.

930 R

Unsigned16

Operating mode
1 : supports the speed control mode and the speed

setpoint channel comprises RFG functionality.

944 R

Unsigned16

Fault message counter

947 R

Array

[1]

Unsigned16

Fault number

963

R

Unsigned16

Detected baud rate:

0 = 9.6 kbit/s
1 = 19.2 kbit/s
2 = 93.75 kbit/s
3 = 187.5 kbit/s
4 = 500 kbit/s
6 = 1.5 Mbit/s
7 =

3 Mbit/s

8 =

6 Mbit/s

9 = 12 Mbit/s

964 R

Array [5]
Unsigned16

Drive Unit identification

IND 0 = PDP003Z ID (0x0C24)
IND 1 = Manufacturer-ID (0x0190)
IND 2 = VF-MB1/S15 CPU1 version
IND 3 = VF-MB1/S15 firmware release year (yyyy)
IND 4 = VF-MB1/S15 firmware release date (ddmm)

965

R

Octet String2

Profile number of the

PDP003Z

(Profidrive, V4.1)

Advertising