How to use – Toshiba Tosvert VF-MB1/S15 User Manual

Page 23

Advertising
background image

E6581738

- 21 -

4.1.

How to use

The purposes are adjustment by real time command transmission, and the monitor of an
operation state by using cyclic communication of PROFIBUS.

Example 1: Command transmitting
When you want to set "0xC400" to parameter fa06, set “1 (fa06)” to parameter

c001

.

And Since 0 and 1 byte of the PZD1 supports the parameter

c001

, if "0xC400" is set up

here, "0xC400" will be set as

fa06

.












Example 2: State monitoring
When you want to monitor the output current, set “3 (FD03)” to parameter

c021

.

The value of the parameter

fd03

specified as 0 and1 byte of the PZD1 with the

parameter

c021

is inputted.














VF-MB1

PDP003Z

"0xC400" is set as parameter fa06

PZD1 PZD2 PZD3

C4

00 ... ... ...

...

PROFIBUS Master

Parameter Value

c001

1 (FA06)

c002

...

c003

...

... ...

Parameter Value

c021

3 (FD03)

c022

...

c023

...

...

...

The value of a parameter fd03 is outputted.

VF-MB1

PDP003Z

PZD1 PZD2 PZD3

xx

xx ... ... ...

...

PROFIBUS Master