10-3. Error Mode Detected by LED on Outdoor P.C. Board

RAV-SM800AT-E

<SW800: LED display in bit 1, bit 2, bit 3, bit 4 OFF>

• When multiple errors are detected, the latest error is displayed.

• While LED displays

(go on), there is the main cause of error in control at CDB side and it stops abnormally.

• While LED displays

(flash), there is the main cause of error in control at IPDU side and it stops abnormally.

• For an error in case thermo operation, the communication is interrupted on the serial circuit. If continuing the

case thermo operation, serial sending to the indoor unit is interrupted and a serial communication error is
output.

CDB side

IPDU side

No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Item

TE sensor error

TD sensor error

TS sensor error

TO sensor error

Discharge temp error

Out DC fan error

Communication error between IPDU
(Abnormal stop)

High-pressure release operation

EEPROM error

Communication error between IPDU
(No abnormal stop)

G-Tr short-circuit protection

Detection circuit error

Current sensor error

Phase missing detection

Comp lock error

Comp breakdown

Check code

B type

18

19

18

1B

1E

1A

1C

21

14

16

17

17

1D

1F

LED display

D800

D801

D802

D803

(Red)

(Yellow)

(Yellow)

(Yellow)

: Go on

: Go off

: Flash (5Hz)