Address: 8 – Toshiba TEC MA-186 User Manual

Page 82

Advertising
background image

- 76 -

EO1-11115

MA-186-100 SERIES

Address:

8

Initial SET Bit Nos.

→

1

Your Selection

→

([Chg] Key Function)

Content

Bit

No.

Selective Status

RESET

SET

Tender and Total Functions in finalizing a sale in REG
mode

-- vacant --

Cashing with no purchase, using this key

Over-tendering (tendering an amount larger than the sale
total, resulting in calculation of change due): effective only
when Bit 1 is RESET

-- vacant --

1

2

3

4

5 to 8

TENDER or

TOTAL

TOTAL only

PROHIBITED

ALLOWED

ALLOWED

PROHIBITED

Supplementary Description for Address 8:

Bit 1:

RESET status .................... The key functions as Tender Key with a prior amount

entry or as Total Key without any amount entry.

SET status .......................... The key functions as Total Key only.

Bit 3:

RESET status .................... Cashing with no purchase is prohibited.
SET status .......................... Cashing with no purchase is allowed outside a sale.

Bit 4:

This Bit status selection is effective only in tendering operation and only when Bit 1 is
RESET.
SET status .......................... If this bit is SET and also Address 11 - Bit 1 is SET (for

Short-tendering Prohibited), an amount equal to the sale
total is always required for tendering.

-- Addresses 9, 10 are vacant. --

Advertising