Tools needed for installation of anti-tip device, 30" and 36" ranges, Important installation information – Thermador PRG30 User Manual

Page 12

Advertising
background image

English 10

reengaged when the range is pushed back

against the wall. In the event of abnormal

usage (such as a person standing, sitting,

or leaning on an open door), failure to take

this precaution can result in tipping of the

range. Personal injury might result from

spilled hot liquids or from the range itself.

WARNING

ELECRICAL SHOCK

HAZARD

Use extreme caution when drilling holes

into the wall or floor. There may be con-

cealed electrical wires located behind the

wall or under the floor.

• Identify the electrical circuits that could be

affected by the installation of the Anti-Tip

Device, then turn off power to these cir-

cuits.

Failure to follow these instructions may

result in electrical shock or other personal

injury.

ATTENTION — PROPERTY DAMAGE

Contact a qualified installer or contractor to determine

the proper method for drilling holes through the wall or

floor material (such as ceramic tile, hardwood, etc.)

Do not slide the range across an unprotected floor.

Failure to follow these instructions may result in

damage to wall or floor coverings.

Tools Needed for Installation of Anti-Tip

Device:

Screwdriver, Phillips

Drill, electric or hand

Measuring tape or ruler

1/8" drill bit (wood or metal wall or floor)

3/16" carbide-tipped masonry drill bit (concrete or

concrete block wall or floor)

3/16" anchors, drywall or concrete, 4 each (not

required if mounting bracket is being attached to solid

wood or metal)

Hammer

Pencil or other marker

30" and 36" Ranges

See Figure

7 and Figure

8.

Important Installation Information:

The anti-tip bracket may be attached to a solid wood

cabinet having a minimum wall thickness of 3/4".

The thickness of the wall or floor may require use of

longer screws, available at your local hardware store.

In all cases, at least two (2) of the bracket mounting

screws must be fastened to solid wood or metal.

Use appropriate anchors when fastening the mounting

bracket to any material other than hard-wood or metal.

Note:

48" Ranges do not require the Anti-Tip Bracket. This is due

to the size and weight distribution of the 48" models.

All Ranges can tip.

Injury to Persons could result.

Install Anti-Tip Device packaged

with range.

Verify that the anti-tip device is

engaged.

See Installation Instructions.

WARNING:

Thermador

Service Part No.

Qty

Description

415078

4

Screw, Phillips,

#10 x 1-1/2"

647936

1

Anti-Tip Bracket,

Floor-Mounted

Figure 7: Anti-tip Bracket

Advertising