English 12

WARNING

Gas line must not come in contact with any

components inside back cover of range.

Hook Up

A manual gas shut-off valve must be installed

external to the appliance, in a location accessible

from the front, for the purpose of shutting off the

gas supply. The supply line must not interfere with the

back of the unit. Make sure the gas supply is turned off

at the manual shut-off valve before connecting the

appliance.

The range is supplied with its own pressure regulator

that has been permanently mounted within the range

body.

Use 3/4" flex line to connect between the gas supply

and the appliance gas inlet, located at the lower right

portion of the range. (See Figure

9.) The appliance inlet

pipe connection is 1/2" NPT. Use caution to avoid

crimping the 3/4" flex line when making bends.

Suggested length of flex line is 48", however, please

check local codes for your area's requirements before

installation.

The gas supply connections shall be made by a

competent technician and in accordance with local

codes or ordinances. In the absence of local codes, the

installation must conform to the National Fuel Gas Code

ANSI Z223.1/NFPA54- current issue.

Always use pipe sealing compound or Teflon® tape on

the pipe threads, and be careful not to apply excessive

force when tightening the fittings.

L

eak testing of the appliance shall be in accordance with

the following instructions.

Turn on gas and check supply line connections for

leaks using a soap and water solution.

Bubbles forming indicate a gas leak. Repair all leaks

immediately after finding them.

WARNING

Do not use a flame of any kind to check for

gas leaks.

CAUTION:

The appliance must be isolated from the gas

supply piping system by closing its individual

manual shut-off valve during any pressure testing

of the gas supply piping system at test pressures

equal to or less than 1/2 psig (3.5kPa.).

The appliance and its individual shut off valve

must be disconnected from the gas supply piping

system during any pressure testing of the system

at test pressures in excess of 1/2 psig (3.5kPa.).

When checking the manifold gas pressure, the

inlet pressure to the regulator should be at least

6.0" (14.9 mb) W.C. for natural gas or 11.0" (27.4

mb) for propane.

Do not attempt any adjustment of the pressure

regulator.

Propane Gas Requirements:

Inlet Connection:

1/2" NPT internal
(Minimum 3/4" dia. flex line.)

Supply Pressure:

11" min. to 14"max. water column.

(27.4 mb to 34.9 mb)

Manifold Pressure:

10" water column (24.9 mb)

Figure 9: Location of Gas Supply Inlet Connection