Step 10: burner test and adjustment, Test rangetop burners, When flame is properly adjusted – Thermador PRG30 User Manual

Page 20: Test oven burners, Test bake burner ignition

Advertising
background image

English 18

Step 10: Burner Test and

Adjustment

Install any loose components, such as burner caps and

grates, that may have been removed earlier. Be certain that

burner caps seat properly into the burner bases. Before

testing operation of the appliance, verify that the unit and

the gas supply have been carefully checked for leaks and

that the unit has been connected to the electrical power

supply. Turn the gas shut-off valve to the open position.

Test Rangetop Burners

Test Burner Ignition. Select a rangetop burner knob.

Push in and turn counterclockwise to

HI. The ignitor/spark

module will produce a clicking sound. Once the air has

been purged from the supply lines, the burner should light

within four (4) seconds.

Test Flame: High Setting. Turn burner on to HI. See

Figure

13 for appropriate flame characteristics.

If any of the rangetop burners continue to burn mostly or

completely yellow, verify that the burner cap is positioned

properly on the burner base, then retest. If flame

characteristics do not improve, call Thermador.

Test Flame: Low Setting. Turn burner on to SIM. Verify

that the flame travels complete around the burner. This is

known as “carry over“. There should be a flame at each

burner port and there should be no air gap between the

flame and the burner. If any burners do not “carry over“, call

Thermador.

The two left burners feature

XLO, that causes the flame to

cycle on and off when the knob is set to the

XLO range.

This is normal operation.

Repeat these Ignition and Flame Test procedures for each

rangetop burner.

When Flame is Properly Adjusted:

There should be a flame at each burner port.

There should be no air gap between the flame and

burner port.

Test Oven Burners

Remove the oven bottom cover. Remove the 4 screws

on the sides and the 2 screws on the back, then slide the

cover forward while lifting to clear the angled baffle plate

mounted to the bottom of the cover.

Note:

The air shutter for the bake burner is set at the factory for

fully-open position under all conditions, and does not

require adjustment.

Test Bake Burner Ignition

Set the oven to

BAKE at 350°F. After 30-75 seconds, the

burner will ignite. The burner will stay lit until 350°F is

reached and then shut off. From this point forward, the

burner will cycle on and off to maintain the temperature.

Figure 13: Flame Characteristics

Yellow Flames:
Further adjustment is required.

Yellow Tips on Outer Cones:
Normal for LP Gas.

Soft Blue Flames:
Normal for Natural Gas.

If the flame is completely or mostly yellow, verify

that the regulator is set for the correct fuel. After

adjustment, retest.
Some orange-colored streaking is normal during

the initial start-up.
Allow unit to operate 4-5 minutes and re-evaluate

before making adjustments.

Advertising