Step 6: Electrical Requirements, Connection & Grounding

Before installing, turn power

OFF at the service panel.

Lock

service panel to prevent power from being turned ON

accidentally.

For these gas range models, a neutral supply wire

must be provided from the power source (breaker/fuse

panel) because critical range components, including

the surface burner spark reignition modules, require

120 VAC to operate safely and properly.

WARNING

An improper 120 VAC power supply will cause

malfunction, damage to this appliance, and

possibly create a condition of shock hazard.

If the correct power supply circuit is not provided, it is

the responsibility and obligation of the installer and

user to have proper power supply connected. This

must be accomplished in accordance with all

applicable local codes and ordinances by a qualified

electrician. In the absence of local codes and

ordinances, the power supply connection shall be in

accordance with the National Electrical Code.

Observe all governing codes and ordinances when

grounding. In the absence of these codes or

ordinances observe National Electrical Code ANSI/

NFPA No. 70 current issue.

Electric wiring diagrams and schematics have been

placed in the toe kick area of the range for access by a

qualified service technician.

Before you plug in an electrical cord, be sure all

controls are in the

OFF position.

For appliances equipped with a cord and plug, do not

cut or remove the ground prong. It must be plugged

into a matching grounding type receptacle to avoid

electrical shock. If there is any doubt as to whether the

wall receptacle is properly grounded, the customer

should have it checked by a qualified electrician.

Installer — show the owner the location of the circuit

breaker or fuse. Mark it for easy reference.

Figure 10: Location of Gas Supply Inlet Connection on 48“

Ranges

A

Chart B: Electrical Supply Circuit Requirements

MODEL

TYPE

VOLTAGE

CIRCUIT

RATING

FREQUENCY

PHASE

30"

120 VAC

10 Amps

60 Hz.

Single

36"

120 VAC

10 Amps

60 Hz.

Single

36" with griddle

120 VAC

20 Amps

60 Hz.

Single

48" with griddle

120 VAC

20 Amps

60 Hz.

Single

Advertising