Prepare holes at fastener locations as identified below:

For walls, wall studs, or floors composed of solid

wood or metal, drill 1/8" pilot holes.

For walls or floors composed of drywall, sheet-rock

or other soft materials, drill 3/16" holes to a mini-

mum depth of 1-3/4", then tap plastic anchors into

each of the holes using a hammer.

For walls or floors composed of concrete or con-

crete block, drill 3/16" holes to a minimum depth of

1-3/4", then tap concrete anchors into each of the

holes using a hammer.

For walls or floors having ceramic tile covering, drill

3/16" holes through the tile only, then drill into the

material behind the tile as indicated immediately

above.

If the range is moved to a new location, the Anti-Tip

Device must be removed and reinstalled.

Mounting Anti-Tip Bracket

The alternative floor mounted bracket shall be installed as

follows:

1. Place bracket on floor in position shown in Figure

8

(Bracket may be used in either corner of the installation

area).

2. Secure to floor or wall stud.
3. Later, when the unit is installed, the adjustable leg will

slide under the bracket.

Step 5: Gas Requirements and

Hookup

Verify the type of gas being used at the installation site.

As

shipped from the factory, units are configured for use

with only natural gas or propane (LP) gas. Make certain

the range matches the type of gas available at this

location. These ranges are NOT convertible between

different types of gas.

For installation of the appliance at high altitude, please

consult your local gas company for their recommendation

of the correct orifice sizes and any other necessary

adjustments that will provide proper gas combustion at

specified altitudes.

CAUTION

When connecting unit to propane gas, make

certain the propane gas tank is equipped with its

own high pressure regulator in addition to the

pressure regulator supplied with the appliance.

The pressure of the gas supplied to the

appliance regulator must not exceed 14"

(34.9

mb) water column.

Figure 8: Placement of Anti-Tip Bracket (Top View)

X

from edge of range

X

typical -

either side

Wall Line

Floor

Right

Cabinet

Front Edge of

Right Cabinet

Left

Cabinet

X = 4-1/2” (for 30” range)

X = 6-3/4” (for 36” range)

Natural Gas Requirements:

Inlet Connection:

1/2" NPT internal
(Minimum 3/4" dia. flex line.)

Supply Pressure:

6" min. to 14" max. water column.
(14.9 to 34.9 mb)

Manifold Pressure:

5" water column (12.5 mb)