Thermador PRG30 User Manual

Page 7

Advertising
background image

English 5

Figure 1: Cabinet Clearances

For Electrical and Gas Supply Zone, see

Figure 3A.

Cooking
Surface

,

CAUTION:

See Figure 2

40" Min. to

combustible

material

Ð

,

from cooking

surface

as defined in the “National Fuel Gas Code” (ANSI Z223.1,
Current Edition). *The range height is adjustable. The level
of the range top must be at the same level or above the
countertop level.

Range width

30", 36" or 48"

30" or 36" Wide Hood

36" or 42" for Island

}

For 30" Ranges

36" or 42" Wide Hood

42" or 48" for Island

}

For 36" Ranges

48", 54" or 60" Wide Hood

54" for Island

}

For 48" Ranges

Min. Distance Between Overhead Cabinets

of Combustible Material

30" Range – 30"

36" Range – 36"

48" Range – 48"

13" Max.

Cabinet

Depth

}

5" Min. to

combustible

side wall

material ,

(both sides)

18"

Min.

*35-7/8" Min. Range Height

with Leveling Legs fully

retracted

*36-3/4" Max. Range Height

with Leveling Legs fully

extended.

30" minimum from bottom of

overhead Hood to cooking

surface (40" min. if hood

contains combustible

materials )