Single outdoor unit

Heat pump Cooling only Nominal

Voltage

Compressor

Fan motor

Power supply

MMY-

MMY-

voltage

range

(V-ph-Hz)

Min.

Max. RLA

kW

FLA

MCA

MOCP

MAP0501HT8 MAP0501T8 400-3-50

342

457

4.0 + 4.0

0.60

0.8

16.5

20

MAP0601HT8 MAP0601T8 400-3-50

342

457

4.6 + 4.6

0.60

0.8

16.5

20

MAP0801HT8 MAP0801T8 400-3-50

342

457

5.2 + 5.2

0.60

1.0

20.0

30

MAP1001HT8 MAP1001T8 400-3-50

342

457

6.5 + 6.5

0.60

1.1

22.5

30

MAP1201HT8 MAP1201T8 400-3-50

342

457

9.5 + 9.5

0.60

1.1

24.5

30

Combination of outdoor units

Heat pump Cooling only Nominal

Voltage

Compressor

Fan motor

Power supply

MMY-

MMY-

voltage

range

Unit No. 1 Unit No. 2 Unit No. 3 Unit No. 4

(V-ph-Hz

Min.

Max. RLA

RLA

RLA

RLA

kW

FLA

MCA

MOCP

AP1401HT8 AP1401T8

400-3-50

342

457

5.2 + 5.2

4.6 + 4.6

0.6 × 2 1.0 + 0.8

36.5

40

AP1601HT8 AP1601T8

400-3-50

342

457

5.2 + 5.2

5.2 + 5.2

0.6 × 2 1.0 + 1.0

40.0

50

AP1801HT8 AP1801T8

400-3-50

342

457

6.5 + 6.5

5.2 + 5.2

0.6 × 2 1.0 + 1.1

42.5

50

AP2001HT8 AP2001T8

400-3-50

342

457

6.5 + 6.5

6.5 + 6.5

0.6 × 2 1.1 + 1.1

45.0

60

AP2201HT8 AP2201T8

400-3-50

342

457

5.2 + 5.2

5.2 + 5.2

4.6 + 4.6

0.6 × 3 1.0 + 1.0 + 0.8

56.5

70

AP2211HT8 AP2211T8

400-3-50

342

457

9.5 + 9.5

6.5 + 6.5

0.6 × 2 1.1 + 1.1

47.0

60

AP2401HT8 AP2401T8

400-3-50

342

457

5.2 + 5.2

5.2 + 5.2

5.2 + 5.2

0.6 × 3 1.0 + 1.0 + 1.0

60.0

70

AP2411HT8 AP2411T8

400-3-50

342

457

9.5 + 9.5

9.5 + 9.5

0.6 × 2 1.1 + 1.1

49.0

60

AP2601HT8 AP2601T8

400-3-50

342

457

6.5 + 6.5

5.2 + 5.2

5.2 + 5.2

0.6 × 3 1.1 + 1.1 + 1.0

62.5

70

AP2801HT8 AP2801T8

400-3-50

342

457

6.5 + 6.5

6.5 + 6.5

5.2 + 5.2

0.6 × 3 1.1 + 1.1 + 1.0

65.0

80

AP3001HT8 AP3001T8

400-3-50

342

457

6.5 + 6.5

6.5 + 6.5

6.5 + 6.5

0.6 × 3 1.1 + 1.1 + 1.1

67.5

80

AP3201HT8 AP3201T8

400-3-50

342

457

5.2 + 5.2

5.2 + 5.2

5.2 + 5.2

5.2 + 5.2

0.6 × 4 1.0 + 1.0 + 1.0 + 1.0

80.0

90

AP3211HT8 AP3211T8

400-3-50

342

457

9.5 + 9.5

6.5 + 6.5

6.5 + 6.5

0.6 × 3 1.1 + 1.1 + 1.1

69.5

80

AP3401HT8 AP3401T8

400-3-50

342

457

6.5 + 6.5

5.2 + 5.2

5.2 + 5.2

5.2 + 5.2

0.6 × 4 1.1 + 1.0 + 1.0 + 1.0

82.5

100

AP3411HT8 AP3411T8

400-3-50

342

457

9.5 + 9.5

9.5 + 9.5

6.5 + 6.5

0.6 × 3 1.1 + 1.1 + 1.1

71.5

80

AP3601HT8 AP3601T8

400-3-50

342

457

6.5 + 6.5

6.5 + 6.5

5.2 + 5.2

5.2 + 5.2

0.6 × 4 1.1 + 1.1 + 1.0 + 1.0

85.0

100

AP3611HT8 AP3611T8

400-3-50

342

457

9.5 + 9.5

9.5 + 9.5

9.5 + 9.5

0.6 × 3 1.1 + 1.1 + 1.1

73.5

90

AP3801HT8 AP3801T8

400-3-50

342

457

6.5 + 6.5

6.5 + 9.5

6.5 + 6.5

5.2 + 5.2

0.6 × 4 1.1 + 1.1 + 1.1 + 1.0

87.5

100

AP4001HT8 AP4001T8

400-3-50

342

457

6.5 + 6.5

6.5 + 6.5

6.5 + 6.5

6.5 + 6.5

0.6 × 4 1.1 + 1.1 + 1.1 + 1.1

90.0

100

AP4201HT8 AP4201T8

400-3-50

342

457

9.5 + 9.5

6.5 + 6.5

6.5 + 6.5

6.5 + 6.5

0.6 × 4 1.1 + 1.1 + 1.1 + 1.1

92.0

110

AP4401HT8 AP4401T8

400-3-50

342

457

9.5 + 9.5

9.5 + 9.5

6.5 + 6.5

6.5 + 6.5

0.6 × 4 1.1 + 1.1 + 1.1 + 1.1

94.0

110

AP4601HT8 AP4601T8

400-3-50

342

457

9.5 + 9.5

9.5 + 9.5

9.5 + 9.5

6.5 + 6.5

0.6 × 4 1.1 + 1.1 + 1.1 + 1.1

96.0

110

AP4801HT8 AP4801T8

400-3-50

342

457

9.5 + 9.5

9.5 + 9.5

9.5 + 9.5

9.5 + 9.5

0.6 × 4 1.1 + 1.1 + 1.1 + 1.1

98.0

110

Legend
MCA

Minimum circuit current, A

FLA

Full load current, A

MOCP Maximum overcurrent protection current, A
kW

Rated fan motor output, kW

RLA

Rated load current, A

Note: RLA is based on the following conditions: