Indoor units ceiling-suspended units – Toshiba SUPER MODULAR MULTI HFC R-410A User Manual

Page 52

Advertising
background image

52

Indoor units

Ceiling-suspended units

Model MMC-AP

0151H

0181H

0241H

0271H

0361H

0481H

Cooling capacity*

kW

4.5

5.6

7.1

8.0

11.2

14.0

Heating capacity

kW

5.0

6.3

8.0

9.0

12.5

16.0

Electrical data
Power supply

V-ph-Hz

230-1-50 (voltage range 220-240 V) - power supply to indoor unit only

Operating current

A

0.29

0.32

0.42

0.42

0.78

0.84

Power input

kW

0.033

0.038

0.050

0.050

0.091

0.110

Starting current

A

0.43

0.48

0.62

0.62

1.17

1.25

Unit appearance

White (Munsell 10Y 9.3/0.4)

Unit dimensions
Height

mm

210

210

210

210

210

210

Width

mm

910

910

1180

1180

1595

1595

Depth

mm

680

680

680

680

680

680

Unit weight

kg

22

22

26

26

34

34

Heat exchanger

Finned tube

Sound proofing/heat insulating material

Non-flammable insulation

Fan type

Centrifugal fan

Fan motor power input

W

30

30

40

40

80

80

Air flow
High

l/s

200

217

308

308

458

500

Medium

l/s

167

183

250

250

383

433

Low

l/s

150

150

233

233

333

367

Air flow
High

m

3

/h

720

780

1110

1110

1650

1800

Medium

m

3

/h

600

660

900

900

1380

1560

Low

m

3

/h

540

540

840

840

1200

1320

Sound power level (high/medium/low)

dB(A)

48/45/43

49/46/43

51/49/46

51/49/46

54/51/48

56/53/50

Sound pressure level (high/medium/low)** dB(A)

35/32/30

36/33/30

38/36/33

38/36/33

41/38/35

43/40/37

Air filter

Standard long-life filter supplied

Controller

Remote controller

Room thermostat

Supplied

Connection pipes
Gas connection diameter

in

1/2

1/2

5/8

5/8

5/8

5/8

Liquid connection diameter

in

1/4

1/4

3/8

3/8

3/8

3/8

Drain connection, nom. dia (polyvinyl tube)

in

3/4

3/4

3/4

3/4

3/4

3/4

Rated conditions:

Cooling: Indoor air temperature 27°C db/19°C wb, outdoor air temperature 35°C db

Heating: Indoor air temperature 20°C db, outdoor air temperature 7°C db/6°C wb

*

Cooling capacities and electrical data are measured at the conditions specified by JIS B 8615, based on the reference piping which consists of 5 m of main
piping and 2.5 m of branch piping connected with 0 metre height.

**

The sound pressure level is measured in an anechoic chamber in accordance with JIS B 8616. Normally the values measured in the actual operating
environment become larger than the indicated values due to the effects of external sound.