White Rodgers 1F92W-51 User Manual

Page 20

Advertising
background image

20

COOLING SYSTEM OPERATION

To prevent compressor and/or property
damage, if power to the compressor has
been off or interrupted for more than 1
hour and the outdoor temperature is be-
low 50

°

F, DO NOT operate the system for

at least the amount of time the compres-
sor was off! This will allow the compres-
sor heaters to warm the compressor oils
to avoid damage due to slugging.

1. Press

SYSTEM

HEAT-OFF-COOL-AUTO

until COOL is displayed.

2. Press

to adjust thermostat to 40

°

F. The

cooling system should come on within approxi-
mately five minutes. However, if the fan is run-
ning but the compressor is not, the compressor
lockout feature is operating (see Lockout By-

pass Option to temporarily override the com-
pressor lockout feature during testing).

3. To program the thermostat, see PROGRAM-

MING YOUR THERMOSTAT.

After heating and cooling system have been checked
and are running properly, determine if automatic
changeover is desired. When option switch #4 is in
the proper position, automatic changeover is en-

abled by pressing

SYSTEM

HEAT-OFF-COOL-AUTO

until AUTO is displayed

(see SET OPTION SWITCHES). In the AUTO mode,
the setpoint temperature is not displayed.

CAUTION

!