White Rodgers 1F92W-51 User Manual

Page 46

Advertising
background image

46

the wall. Then press

SYSTEM

HEAT-OFF-COOL-AUTO

for desired sys-

tem operation, and press

RUN

PRGM

to begin the

factory preset program. Or you may re-program
the thermostat, then replace it on the wall.

To prevent further static discharge problems,
touch another object to release static build-up
before touching the thermostat. See OPERAT-
ING YOUR THERMOSTAT
.

7. Why won’t the setpoint temperature go to the

temperature I want?

In the AUTO mode, the highest heating setpoint
temperature you select must be at least 1

°

F

lower than the lowest cooling setpoint tempera-
ture you select (for example, if 70

°

F is your

lowest selected cooling temperature, you cannot
select a heating temperature any higher than
69

°

F). If such a conflict exists, you must set the

lowest cooling temperature higher in order to set

the heating temperature higher. To set a lower
cooling temperature, you must select a lower
heating temperature. See PROGRAMMING
YOUR THERMOSTAT
.

8. The display is flashing BAT. What does this

mean?

The 9 volt battery installed in the thermostat is
low and should be replaced with a fresh 9 volt
Energizer

®

alkaline battery. See OPERATING

YOUR THERMOSTAT.

9. The display shows a continuous (non-flash-

ing) BAT. What does this mean?

The thermostat is not being supplied with 24 VAC
power. The thermostat is operating on battery
power alone. See OPERATING YOUR THER-
MOSTAT
.