Western Telematic NBB-1600-D20 User Manual

Page 26

Advertising
background image

5-4

NBB-1600-D20/D16 Series: Network Boot Bars - User's Guide

5.2.2. Accessing the Text Interface
The Text Interface can be accessed via Network, modem or local PC. In order

to access the Text Interface, your installation must include the following:

Access Via Network: The NBB must be connected to your TCP/IP

Network, and your PC must include a communications program (such as

Hyperterminal™.)

Access Via Modem: An external modem must be connected to the

NBB’s Console Port, and a phone line must be connected to the external

modem. Your PC Must include a communications program.

Access Via Local PC: Your local PC Must be connected to the NBB’s

Console Port. The local PC must include a communications program.

To access command mode via the Text Interface, proceed as follows:

1. The NBB is transparent to parity and will accept 7 or 8 bit characters,

but will always answer back at 8 bits, no parity. Make certain your

communication program is set for the appropriate baud rate, bits, parity

and Comm Port.
a) Via Modem: Start your communications program. Dial the

external modem connected to the NBB. Wait for the Connect

message, then proceed to Step 2.

b) Via Local PC: Start your communications program and press

[Enter]. Wait for the connect message, then proceed to Step 2.

Network Boot Bar v1.41c Site ID: (undefined)

Plug | Name | Password | Status | Boot/Seq. Delay | Default |

-----+------------------+-------------+--------+-----------------+---------+

1 | Server_1 | (defined) | ON | 15 Secs | ON |

2 | Server_2 | (defined) | ON | 15 Secs | ON |

3 | Server_3 | (defined) | ON | 15 Secs | ON |

4 | Server_4 | (defined) | ON | 15 Secs | OFF |

5 | Router_1 | (defined) | ON | 0.5 Secs | ON |

6 | Router_2 | (defined) | ON | 0.5 Secs | ON |

7 | Router_3 | (defined) | ON | 0.5 Secs | OFF |

8 | DSU-CSU_A | (defined) | ON | 1 Sec | ON |

9 | DSU-CSU-B | (defined) | ON | 1 Sec | OFF |

10 | Ethernet_Switch | (defined) | ON | 0.5 Secs | ON |

11 | atmswitch_1 | (defined) | ON | 2 Secs | ON |

12 | atmswitch_2 | (defined) | ON | 2 Secs | ON |

13 | atmswitch_3 | (defined) | ON | 2 Secs | OFF |

14 | LINUX_1 | (defined) | ON | 5 Secs | ON |

15 | LINUX_2 | (defined) | ON | 5 Secs | OFF |

16 | Modem | (defined) | ON | 30 Secs | ON |

-----+------------------+-------------+--------+-----------------+---------+

“/H” for help.

NBB>

Figure 5.2: Plug Status Screen - Text Interface (Sample Values Shown)