Western Telematic NBB-1600-D20 User Manual

Page 30

Advertising
background image

5-8

NBB-1600-D20/D16 Series: Network Boot Bars - User's Guide

The General Parameters Menu allows the following parameters to be defined.

System Password: The NBB will display a password prompt when

you attempt to access command mode. When the System Password

is entered at log on, the System Mode will be active, allowing access

to both switching functions and configuration menus. (16 Characters,

Default = undefined.)

Notes:

• If the System Password is not defined, then the NBB will start

up in System Mode, and configuration functions will then be

available to anyone who accesses Command Mode.

• Passwords and User Names cannot contain nonprintable

characters, spaces, colons (

:), plus signs (+) or

quotation marks.

User Name: (Optional) The User Name allows you to set up an

additional layer of security for web access to the command mode by

requiring that users correctly enter a name in addition to a password.

Note that the User Name is only required when the unit is accessed via

the Web Interface. (16 Characters, Default = undefined.)

Notes:

• If a User Name is defined, then users who log in with a Plug

Password (User Mode) will also need to enter this same User

Name at the login prompt when attempting to access command

mode via the Web Browser Interface.

• The User Name cannot begin with a forward slash (

/) or

backslash (

\) character, and cannot include non-printable

characters, space characters, asterisks (

*) or quotation marks.

Site ID: Defines a brief text message, which can be used to describe the

location of the NBB unit. (Up to 32 characters, Default = undefined.)
Note:

The Site ID Message cannot begin with a forward slash

(

/) or backslash (\)character and cannot include non-printable

characters or quotation marks.

Command Echo: Enables/Disables command echo. When enabled,

ASCII commands sent via the Text Interface to the NBB will be echoed

back, allowing keystrokes to be displayed. Note that this feature applies

primarily to the text interface, and has no visible effect on the Web

Browser Interface. (Default = On.)