SPECIFYING DYNAMIC JOB DESCRIPTOR ENTRIES (DJDES)

XEROX DOCUPRINT 180 LPS PDL REFERENCE

8-15

Changing the online BANNER offset criteria or VOLUME command
OPTIMIZE parameter in a selected JDE causes unpredictable results
and should not be attempted.

The selected JDE should specify all JDE parameters which stay the
same as the original JDE as well as the changes. The parameters
which can be changed through a selected JDE are listed in table 8-9.

If a front cover is invoked in a selected JDE which takes effect after
the first page of the report, a cover is pulled from the AUX tray at the
point where the DJDE is applied.

Note:

CODE changes to data may occur and will take effect on the

page boundary following the DJDE record. If a translation code
change is involved in a selected JDE, the parameter portion of any
subsequent DJDE must be in the new code. The prefix used by the
IDEN must, however, retain the original hexadecimal value. Thus, if
the CODE changes from EBCDIC to ASCII, the prefix must remain in
EBCDIC even though the parameter portion changes to ASCII.

BLOCK

All parameters

RECORD

All parameters

BANNER

All parameters

Table 8-9.

Parameters which can be changed through a JDE

Command

Parameter(s)

LINE

DATA
FONTINDEX
MARGIN
OVERPRINT
PCCTYPE
VFU

LINE

All parameters except OFFSET

VOLUME

TCODE
CODE

ACCT

All parameters

EXPORT

All parameters

MESSAGE

All parameters

PDE

All parameters

ROUTE

All parameters

ROFFSET

All parameters

RAUX

All parameters

RPAGE

All parameters

RSTACK

TEST (online only)

Table 8-8.

Parameters which cannot be changed through a
JDE
(continued)

Command

Parameter(s)