Sfp module connector, Table 1-9 – Xilinx ML605 User Manual

Page 37

Advertising
background image

ML605 Hardware User Guide

www.xilinx.com

37

UG534 (v1.8) October 2, 2012

Detailed Description

References

See the following websites for more Virtex-6 FPGA Integrated Endpoint Block for PCI
Express information:

http://www.xilinx.com/products/ipcenter/V6_PCI_Express_Block.htm

http://www.xilinx.com/support/documentation/ipbusinterfacei-o_pci-
express_v6pciexpressendpointblock.htm

In addition, see the PCI Express specifications for more information.

[Ref 27]

10. SFP Module Connector

The board contains a small form-factor pluggable (SFP) connector and cage assembly that
accepts SFP modules. The SFP interface is connected to MGT Bank 116 on the FPGA. The
SFP module serial ID interface is connected to the “SFP” IIC bus (see

15. IIC Bus, page 44

for more information). The control and status signals for the SFP module are connected to
jumpers and test points as described in

Table 1-9

. The SFP module connections are shown

in

Table 1-10, page 38

.

Table 1-9:

SFP Module Control and Status

SFP Control/Status

Signal

Board Connection

SFP_TX_FAULT

Test Point J52

High = Fault

Low = Normal Operation

SFP_TX_DISABLE

Jumper J65

Off = SFP Disabled

On = SFP Enabled

SFP_MOD_DETECT

Test Point J53

High = Module Not Present

Low = Module Present

SFP_RT_SEL

Jumper J54

Jumper Pins 1-2 = Full Bandwidth

Jumper Pins 2-3 = Reduced Bandwidth

SFP_LOS

Test Point J51

High = Loss of Receiver Signal

Low = Normal Operation

Advertising