Important Safety Instructions
1. Before installing the Long AC Conduit Box, read all instructions and
cautionary markings on the Long AC Conduit Box and all appropriate 
sections of this guide.
2. Do not expose the Long AC Conduit Box to rain, snow, or spray. 
3. To reduce risk of fire hazard, do not cover or obstruct the ventilation 
openings.
4. Do not install the Long AC Conduit Box in a zero-clearance compartment.
Overheating may result. Minimum clearance for ventilation around the unit 
must be twelve inches above and around the sides of the unit. See “Ventilation 
Requirements” on page 2–5 for additional information.
5. Do not store anything flammable near the unit. Relocate anything flammable
to another location.
6. Xantrex offers CSA “approved” parts for installation into this product. Parts
purchased elsewhere are subject to approval by the local electrical authority.
See Figure 2-11 on page 2–16 for details.
7. The Long AC Conduit Box is designed to be permanently connected to your
Sine Wave Plus inverter. Xantrex recommends that all wiring be done by a 
certified technician or electrician to ensure adherence to the local and national 
electrical codes applicable in your application.
8. To avoid a risk of fire and electric shock, make sure that existing wiring is in
good condition and that wire is not undersized. Do not operate the Long AC 
Conduit Box, or inverter, with damaged or substandard wiring.
9. To reduce the risk of electrical shock, disconnect all power to the Long AC
Conduit Box and the Sine Wave Plus Inverter/Charger before attempting any 
maintenance or cleaning or working on the Long AC Conduit Box. 
10. The Long AC Conduit Box is provided with an equipment-grounding bar
which must be connected to the inverter/system equipment ground.
WARNING
This chapter contains important safety and operating instructions for the Sine Wave Plus 
Long AC Conduit Box (ACCB-L and ACCB-L-L1) and the ACCB-L-L2 (ACCB-L2-PCK 
add-on package). Read and keep this Sine Wave Plus AC Conduit Box Long Owner’s 
Guide for future reference.