Environmental/electrical requirements

Your DocuPrint 96/DocuPrint 96MX LPS has important
environmental and electrical requirements that must be
accommodated. These requirements are summarized in the table
below. For further details on electrical requirements, refer to the
following voltage charts and wiring diagrams.

Table 3-6.

DocuPrint 96/DocuPrint 96MX Environmental and
electrical requirements

Environmental requirements

Operating temperature

Recommended:

Minimum:

Maximum:

72° F ± 4° F/22° C ± 2° C

60° F/15.5° C

80° F/29.5° C

Humidity

Recommended: 4

Minimum:

Maximum:

45% ± 10%

15%

85%

Altitude

Normal:

Maximum:

Up to 6,000 feet/1830 m above sea level

9,000 feet/2743 m above sea level

Heat dissipation

System controller

Operating:

Standby:

4,354 Btu per hour

2,485 Btu per hour

Peripheral cabinet (fully configured)

Operating:

Standby:

3,195 Btu per hour

1,775 Btu per hour

Printer

Operating:

Standby:

28,140 Btu per hour

4,454 Btu per hour

System controller

U.S. and Canada, 60
Hz:

International, 50 Hz:

208/240 VAC (1 phase) or 208/220 VAC
(2 phase)

15 amp service

NEMA 6-15R or ANSI C73, 20R

KVA 1.1 (operating)

200/240 VAC +/-10%

15 amp service;

Power connector per local codes