PREINSTALLATION
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE
3-21
50 Hz system controller and peripheral cabinet power cord configurations
Figure 3-11 shows the 50 Hz system controller power cord
configuration.
Figure 3-11. System controller and peripheral cabinet power
cord 50 Hz installation 200/230 VAC, single phase,
15A
Note:
The 50 Hz plug and receptacle specifications vary according
to local codes.
60 Hz printer outlet voltages
Note:
All power outlets must have a dedicated circuit for each
system equipment piece. Ensure that each power cord has a
separate circuit.
Refer to table 3-12 for the 60Hz voltage requirements at the power
outlet.
Table 3-12.
Printer (50 Hz) voltage requirements at power
outlet
Service outlet
configuration
Measurement
Nominal
Range
4 Wire
Line 1 to Neutral
120 V RMS
107-127 V RMS
4 Wire
Line 2 to Neutral
120 V RMS
107-127 V RMS
4 Wire
Neutral to
Ground
0 V RMS
0-10 V RMS
4 Wire
Line 1 to Line 2
208 V RMS
182-220 V RMS
Line 1 to Line 2
240 V RMS
210-254 V RMS