DocuPrint 96/DocuPrint 96MX LPS power receptacle requirements

All power outlets must be dedicated only to this equipment. Ensure
that each power cord has a separate circuit.

You must use a power cord assembly (ELCI, RCD Inline, 220 VAC)
when using a source other than the system controller to provide
power to your keyboard/display. Contact your sales and service
representative to ensure the proper assembly is ordered and
installed.

Ensure that the power cord configurations match your receptacle
requirements (tables 3-7 and 3-8).

50 Hz systems: Consult with your local service representative to
determine the type of plug and receptacle to use with your 50 Hz
printer and system controller.

Table 3-7.

Printer power receptacle requirements

Electrical environment

Voltage/current

Receptacle

U.S. and Canada 60 Hz

120/240/50A or

120/208/50A

NEMA 14-50R

International 50 Hz WYE

380, 400, 415/20A (WYE), 3
Phase, 5 wire

Per local code

International 50 Hz DELTA

220, 230, 240/30A (DELTA),

3 Phase, 4 wire

Per local code

Table 3-8.

System controller and peripheral cabinet power
receptacle requirements

Electrical environment

Voltage

Current

Receptacle

U.S. and Canada 60 Hz

208/240, 1 Phase or

220/230 (L1-L2)

15A

NEMA 6-15R or
ANSI C73,

20R

International 50 Hz

220/230, 1 Phase

15A

Per local code