Xerox 721P85600 User Manual
Page 50

PREINSTALLATION
3-20
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE
50 Hz DELTA printer outlet voltages
Note:
All power outlets must be dedicated only to this equipment.
Ensure that each power cord has a separate circuit.
50 Hz DELTA configurations only: Measure the DELTA connection
voltages at the power source. The required voltages are shown in
table 3-11.
Consult with your service representative to determine the type of plug
and receptacle to be used for your 50 Hz printer.
Table 3-11.
Printer (50 Hz only) DELTA connection for 220/230/
240 V Service outlet
Service outlet
configuration
Measurement
Nominal
Range
4 Wire 220 V
Line 1 to Line 2
220 V RMS
198-242 V RMS
4 Wire 220 V
Line 2 to Line 3
220 V RMS
198-242 V RMS
4 Wire 220 V
Line 1 to Line 3
220 V RMS
198-242 V RMS
4 Wire 230 V
Line 1 to line 2
230 V RMS
207-253 V RMS
4 Wire 230 V
Line 2 to line 3
230 V RMS
207-253 V RMS
4 Wire 230 V
Line 1 to line 3
230 V RMS
207-253 V RMS
4 Wire 240 V
Line 1 to Line 2
240 V RMS
216-264 V RMS
4 Wire 240 V
Line 2 to Line 3
240 V RMS
216-264 V RMS
4 Wire 240 V
Line 1 to Line 3
240 V RMS
216-264 V RMS