Zebra 105SL User Manual

Page 104

Advertising
background image

Configuration
Control Panel Parameters

96

11342L-001 Rev. A

105SL User Guide

6/30/06

These parameters are automatically set during the calibration procedure
and should be changed only by a qualified service technician. Refer to the
ZPL II Programming Guide for information on these parameters.

To skip these parameters:

1.

Press

PLUS (+)

repeatedly.

Adjust LCD Display
This parameter allows you to adjust the brightness of your LCD if it is
difficult to read.

Default: 10

Range: 00 to 19

To change the value shown:

1.

Press

PLUS (+)

to increase the value (increase brightness).

2.

Press

MINUS (-)

to decrease the value (reduce brightness).

Select Format Convert
Selects the bitmap scaling factor. The first number is the original dots per
inch (dpi) value; the second, the dpi to which you would like to scale.

Default: NONE

Selections:

NONE, 150

→ 300, 150 → 600, 200 → 600, 300 → 600

To change the value shown:

1.

Press

PLUS (+)

or

MINUS (-)

to scroll through the options.

Table 9 • Printer Parameters (Page 18 of 19)

Parameter

Action/Explanation

WEB S. 073

- +

MEDIA S. 075
- +

RIBBON S. 071

- +

- +

MARK S. 000

- +

MARK MED S. 000

- +

MEDIA LED 082

- +

RIBBON LED 008

- +

MARK LED 005
- +

LCD ADJUST +10
- +

FORMAT CONVERT

- NONE +

Advertising