Electrical specifications
210 to 246 VAC
Voltage
Scanner
120 VAC
Printer
Single phase 214 to 250 VAC
Three phase 185 to 215 VAC
Current (Amps)
Scanner
20 A
Printer
30 A
Power consumption (Watts)
Scanner
Printer
Running
1100
5800
Standby
1000
5100
Environmental data
Operating range
Relative humidity
15% to 85%
Temperature
50
0
F to 90
0
F
Heat output
Running
11,068 BTU/hr.
Standby
2700 BTU/hr.
Audible noise (scanner and printer)
Running
49.5 db (A) or less
Standby
64 db (A) continuous
72 db (A) maximum
Ozone
Concentration based on simulation model:
Daily copy volume: 8250 copies/8 hours
Room size: 17 m
3
0 Air changes per hour
77.6 ug/min
0.009 ppm (time weighted average)
0.016 ppm (peak) threshold limit value (0.10
ppm)
Total dust
0.04 mg/m
3
threshold limit value (10
mg/m
3
)
Organics
<10ppb