Zhone Technologies 4000E User Manual

Page 12

Advertising
background image

12

4000E IP Broadband Loop Carrier Installation Instructions

IPD4-A2-ZZ40-20

and insert the screw into the same "+" terminal from which it was

removed.

5 Remove the right-hand screw (labeled "–") from the same terminal block.

Slide the ring terminal of your NEGATIVE lead around the shaft of the

screw and insert the screw into the same "–" terminal from which it was

removed.

6 Connect both power leads to a fuse panel. The negative (–) lead connects

to a "Batt" (Battery) terminal and the positive (+) lead connects to a

"Return" terminal on your DC power supply.

CAUTION:

Observe proper polarity.
The power source(s) connected to the 4000E must be equipped with a

disconnect device such as an On/Off switch. Otherwise, an

appropriately rated circuit breaker must be installed on each power

circuit to be used. In the case of an emergency, hazardous voltages

will not be removed from the 4000E until all power sources have

been either turned off or disconnected from the chassis.

Positive (+)

Terminal

Positive Power Lead

Ring Terminal

DC Power Terminal

05-17835

– 48V

10A

– 48V

10A

Negative (–)

Terminal

Negative Power Lead

Ring Terminal

DC Power Terminal

05-17836

– 48V

10A

– 48V

10A

Advertising