Zhone Technologies 4000E User Manual

Page 14

Advertising
background image

14

4000E IP Broadband Loop Carrier Installation Instructions

IPD4-A2-ZZ40-20

1 Identify the appropriate RJ21 Connector. Subscriber lines must be

connected according to the 4000E slot in which the corresponding

interface module was installed. Interface module slots 1–4 run from

bottom to top; the corresponding RJ21 ports are directly behind each slot

on the back of the chassis (1–4, bottom to top). Each interface module slot

on the 4000E has two corresponding RJ21 connectors on the back of the

chassis: the RJ21 connectors on the left (A) provide the subscriber

connections for interface module ports 1–24 (on most models) and the

RJ21 connectors on the right (B) provide the subscriber connections for

interface module ports 25–48 (on applicable models). For the

TIM1500-24 and EIM2000-24 interface modules, the A connectors

provide the subcriber connections for ports 1-12 and the B connectors

provide the subscriber connections for ports 13-24.

2 Detach the hook-and-loop fastener Strap from the female RJ21 connector

port: lift the hook-and-loop fastener tab from the bottom and pull the strap

upward to open, leaving it looped under the right side of the connector

frame.

3 Slide the male RJ21 connector of your interface cable underneath the

hook-and-loop fastener, from the left, and press it firmly into the female

RJ21 connector port on the chassis.

05-17839

4000E Rear View

Interface Module B

Connectors

Interface Module A

Connectors

Subscriber connections for ports

25-48 (on applicable models)

Subscriber connections for ports

1-24 (on most models)

4A

3A

2A

1A

4B

3B

2B

1B

– 48V

10A

05-17840

Female RJ21

Connector A

for Interface

Module Slot 3

05-17841

Male RJ21

Connector of

Your Interface

Cable

Advertising