ACU-RITE VRO 300M User Manual

Page 70

Advertising
background image

VRO 300M

Troubleshooting

63

If the system seems to be displaying incorrect positions, check the following

items.

Verify presets.

Make sure the numbers that you entered are correct.

Verify tool.

Check that the correct tool is being used. Make sure the

correct tool offset has been entered. Check the tool for wear.

Verify the scale factor.

Ensure that the correct scale factor is being used.

Verify linear error compensation.

Make sure that the factors used for

linear error compensation are correct.

Errors

The readout includes built-in test and error-checking circuitry. This circuitry
identifies errors that occur, and reports the problem to the operator.

Loss of power is indicated by the “Power was off” message. Loss of power

means that power to the readout has been interrupted. Since power to the
encoders has also been interrupted, position information may no longer be
accurate. Press the

CLEAR

key to clear the error message. Refer to page 7 for

information about position recovery.

Counting errors are indicated by the “Scale miscount” message, telling you in

which axis the miscount occurred. Counting errors result from distorted
electrical signals from an encoder. These signals can be a result of an encoder
malfunction, misalignment, mounting problems, or electrical interference.
Press the

CLEAR

key to clear the error message. Follow these steps to determine

if your difficulties are associated with the readout or with the encoder.

Ensure that the linear encoder connectors are correctly seated.

Swap linear encoder cables at the readout to see if the problem still
appears in the same display.

If the problem remains in the same display, the readout is in error.

If the problem follows the connection change, the linear encoder may be
in error. Refer to the Checking the Linear Encoders section of your encoder
reference manual.

Display overflow errors are indicated by a blank axis display. A numeric

overflow occurs when the intended measurement is too large for the eight-
digit display. Clear the error by returning the machine table into an area
where measurements can again be displayed, setting a new preset, or zeroing
the display.