Bosch ALS 25 User Manual

Page 14

Advertising
background image

F 016 L70 799 | (5.4.11)

Bosch Power Tools

14 | English

Note: If an extension cable is used it must be earthed

and connected through the plug to the earth cable of

your supply network in accordance with prescribed

safety regulations.
If in doubt contact a qualified electrician or the near-

est Bosch Service Centre.
f

WARNING! Inadequate extension cables can be

dangerous. Extension cable, plug and socket

must be of watertight construction and intended

for outdoor use.

It is recommended for increased electrical safety to

use a Residual Current Device (RCD) with a tripping

current of not more than 30 mA. Always check your

RCD every time you use it.
For products not sold in GB:

WARNING: For your safety, it is required that the plug

attached to the machine is connected with the exten-

sion cord. The coupling of the extension cord must be

protected against splash water, be made of rubber or

coated with rubber. The extension cord must be used

with a cable strain relief.
The connection lead must be inspected for signs of

damage at regular intervals and may only be used if in

perfect condition.
If the supply cord is damaged, it must be replaced by

a Bosch Service Centre.
Products sold in GB only: Your product is fitted with

a BS 1363/A approved electric plug with internal fuse

(ASTA approved to BS 1362).

If the plug is not suitable for your socket outlets, it

should be cut off and an appropriate plug fitted in its

place by an authorised customer service agent. The re-

placement plug should have the same fuse rating as

the original plug.

The severed plug must be disposed of to avoid a pos-

sible shock hazard and should never be inserted into a

mains socket elsewhere.

Products sold in AUS and NZ only: Use a residual cur-

rent device (RCD) with a rated residual current of

30 mA or less.

Maintenance

f

Keep all nuts, bolts and screws tight to ensure that

the leaf blower/garden vacuum is always in a safe

working condition.

f

The leaf blower/garden vacuum should be stored

in a dry, high or locked up place out of the reach of

children.

f

Replace worn or damaged parts for safety.

f

Check the collection bag frequently for wear or de-

terioration.

f

Do not attempt to repair the machine unless you

are qualified to do so.

f

Ensure replacement parts fitted are Bosch ap-

proved.

Symbols

The following symbols are important for reading and

understanding the operating instructions. Please take

note of the symbols and their meaning. The correct in-

terpretation of the symbols will help you to use the

garden product in a better and safer manner.

Intended Use

The product is indented for blowing and collecting

leaves, garden waste such as grass and twigs in the ar-

ea around the garden and house.

Technical Data

Noise/Vibration Information

Measured sound values determined according to

EN 60335.
Typically the A-weighted noise levels of the product

are: Sound pressure level 82 dB(A); sound power level

102 dB(A). Uncertainty K =3 dB.

Wear hearing protection!
Vibration total values a

h

(triax vector sum) and uncer-

tainty K determined according to EN 60335:

a

h

<2.5 m/s

2

, K =1.5 m/s

2

.

Declaration of Conformity

We declare under our sole responsibility that the prod-

uct described under “Technical data” is in conformity

with the following standards or standardization docu-

ments: EN 60335 according to the provisions of the di-

rectives 2004/108/EC, 2006/42/EC, 2000/14/EC.

2000/14/EC: Guaranteed sound power level

105 dB(A). Conformity assessment procedure accord-

ing to Annex V.
Equipment category: 34, 35
Technical file at:

Bosch Lawn and Garden Ltd., PT-LG/EAE,

Stowmarket, Suffolk IP14 1EY, England

Robert Bosch GmbH, Power Tools Division

D-70745 Leinfelden-Echterdingen

01.04.2011

Symbol

Meaning

Blow mode

Vacuum mode

Reaction direction

Movement direction

Switching On

Switching Off

Permitted action

Prohibited action

Wear protective gloves.

Only operate with assembled

tube.

Leaf blower/

Garden Vacuum

Cleaner

ALS 25

ALS 25

Article number

3 600 ...

HA1 0.. HA1 030

Rated power input

W

2500

2300

Air speed, max.

km/h

300

300

Volume flow rate, max.

m

3

/h

800

800

Shredding ratio

10:1

10:1

Collection bag volume

l

45

45

Weight (blow mode)

kg

3.2

3.2

Weight (vacuum

mode)

kg

4.4

4.4

Protection class

/

II

/

II

Serial number

see type plate on the garden

product

The values given are valid for a nominal voltage [U] of

230 V. For different voltages and models for specific

countries, these values can vary.
Please observe the article number on the type plate

of your garden product. The trade names of the indi-

vidual garden products may vary.
Starting cycles generate brief voltage drops. Interfer-

ence with other equipment/machines may occur in

case of unfavourable mains system conditions. Mal-

functions are not to be expected for system imped-

ances below 0.36 ohm.

Dr. Egbert Schneider

Senior Vice President

Engineering

Dr. Eckerhard Strötgen

Head of Product

Certification

Symbol

Meaning

OBJ_BUCH-1436-001.book Page 14 Tuesday, April 5, 2011 10:07 AM

Advertising