Additional specifications, Input conditions, Additional characteristics – American Magnetics 12200PS DC Power Supply (CE-Marked) User Manual

Page 13

Advertising
background image

FEATURES AND SPECIFICATIONS

OPERATING MANUAL

1-4

Release 1.0 (98/07)

1.3.2

Additional Specifications

Rise Time (No Load, Full Load):

1

7.5V to 60V models: 100 ms; 100V to 600V models: 170 ms

Fall Time (No Load):

2

4 s

Fall Time (Full Load):

3

7.5V to 60V models: 100 ms; 100V to 600V models: 170 ms

Voltage Mode Transient Response:

4

<3 ms

Time Delay from power on until output stable

7 seconds maximum

1.3.3 Input

Conditions

AC Input Voltage Ranges

190-264Vac, 1

φ

(24.3A maximum at 208Vac; 22.4A

maximum at 230Vac)

Source Frequency

47-63Hz

Power Factor

0.65 typical

Figure 1.3-1 Typical Input Current Characteristics

(Based on 100V, 28A model.)

1.3.4

Additional Characteristics

Switching Frequency

Nominal 31kHz (62kHz output ripple)

Output Hold-up Time

Greater than 10 ms with interruption of AC line, for
nominal AC input and full load

Maximum Voltage Differential
from either output to safety ground

600Vdc

1 Measured with stepped 0-10V analog programming source and a resistive load.
2 Measured with stepped 0-10V analog programming source and a resistive load.
3 Measured with stepped 0-10V analog programming source and a resistive load.
4 Time for the output voltage to recover within 0.5% of its previous level after a step change in load current of 10% to 90% of

rated output. Load slew rate <6A/

µ

s.

I

N
P
U

T

C
U
R
R
E
N

T

(A)

OUTPUT VOLTAGE

25

20

15

10

5

50%

100%

50% at 190Vac

100% at 264Vac

0

O
U

T
P

U

T

C
U
R
R
E
N

T

100% at 190Vac

50% at 264Vac

30