REMOTE OPERATION

OPERATING MANUAL

4-2

Release 1.0 (98/07)

4.2.1

Rear Panel SW1 Switch (continued)

The rear panel SW1 switch is marked with the word OPEN on its upper surface. Any of the eight switches on
SW1 is OFF when it has been flipped up to break contact, ON when flipped down to close contact. Table 4.2-1
shows the functions assigned to each SW1 switch.

Table 4.2-1 Rear Panel SW1 Switch Assignments (Factory Defaults Underlined)

Switch

Function

Open

Closed

SW1-1

1mA current source for resistive programming
of output voltage

Voltage source
programming

Resistive programming
(0-5k, 0-10k)

SW1-2

1mA current source for resistive programming
of output current limit

Voltage source
programming

Resistive programming
(0-5k, 0-10k)

SW1-3

Output voltage programming source range
select

0-5V (0-5k)

0-10V (0-10k)

SW1-4

Output current limit programming source range
select

0-5V (0-5k)

0-10V (0-10k)

SW1-5

Output voltage monitor range select

0-5V

0-10V

SW1-6

Output current monitor range select

0-5V

0-10V

SW1-7

Remote shutdown logic select

HIGH=OFF

HIGH=ON

SW1-8

Over temperature shutdown reset mode select

Auto reset

Latch OFF

Resetting the Switches

Before making any changes to the switch settings, disable the power supply output by pushing the front panel
STANDBY switch to its IN position. This shuts down the power supply on a temporary basis. The front panel
S/D LED turns on. Then, use any small, flat-bladed screwdriver to change the switch settings.

4.2.2

Rear Panel J2 Connector

The J2 Programming and Monitoring connector is a 15-terminal wire clamp connector located on the power
supply's rear panel. See Figure 4.2-2. The J2 connector provides access to the following functions:

Remote programming of output voltage AND/OR current limit

Remote monitoring of calibrated readback signals for output voltage and output current

Remote control of the shutdown function using a 2.5 to 15V signal

Figure 4.2-2 Programming and Monitoring J2 Connector

1 Remote Output Voltage Programming Select
2 Remote Output Current Limit Programming Select
3 Control Ground
4 No connection
5 Voltage Program Signal Return
6 Output Voltage Programming Input
7 Current Program Signal Return
8 Output Current Limit Programming Input
9 Voltage Monitor Signal Return
10 Output Voltage Monitor
11 Current Monitor Signal Return
12 Output Current Monitor
13 No connection
14 Shutdown (S/D) Signal Return (-)
15 S/D Input (+)