Remote programming and monitoring, Environmental specification, Mechanical specification – American Magnetics 12200PS DC Power Supply (CE-Marked) User Manual

Page 14

Advertising
background image

OPERATING MANUAL

FEATURES AND SPECIFICATIONS

Release 1.0 (98/07)

1-5

1.3.5

Remote Programming and Monitoring

Remote Analog Programming (Full Scale Input)

Voltage and current programming:
0-5k, 0-10k resistances; 0-5V, 0-10V voltage sources

Remote Monitoring

Output voltage and current: 0-5V, 0-10V
0 to full scale output 1% accuracy.

Maximum Remote Sense Line Drop Compensation

5V/line (Line drop is subtracted from total voltage
available at supply output.)

Remote Start/Stop and Interlock

2.5-15V signal or TTL-compatible input, selectable logic

Optional Isolated Program and Readback (V&I)

0-5V (ISOL Interface)

Optional Digital Control

RS-232, GPIB Interfaces

1.3.6 Environmental

Specification

Operating Temperature Range

0°C to 50°C

Storage Temperature Range

-20°C to +70°C

Humidity Range

30% to 90% RH Non-condensing

Operating Altitude

Derate maximum operating temperature by 1°C per 1,000
feet (300 m) for operation between 5,000 feet (1500 m)
and 15,000 feet (4500 m).

Storage Altitude

Up to 50,000 feet (15 000 m).

Installation Category

Intended for use in installation category (overvoltage
category) II (IEC 1010-1 standard).

1.3.7

Mechanical Specification

Front Panel Control

10-turn voltage and current potentiometers

Front Panel Voltage Control Resolution

0.02% of V max

Meter Accuracy

See Table 1.3-1 and Table 1.3-2

.

AC Input Connector Type

3-terminal, 34A, 250V, right angle, PC mount,
wire clamp connector with strain relief cover

Output

7.5V to 100V models: nickel-plated copper bus bars with
bus bar cover and strain relief; bus bar holes: 0.343"
(8.7 mm) D (1), 0.197" (5.0 mm) D (2);

150V to 600V models: 4-terminal, right angle, PC mount,
wire clamp connector

Sense Connector

5-terminal wire clamp connector (2 piece)

Analog Programming Connector

15-terminal wire clamp connector (2 piece)

Chassis Ground

One chassis ground screw located on rear panel for
bonding connections

Cooling

Fan cooled. Air exhausts to rear. Over temperature
shutdown: automatic restart or latch off.

Mounting

Removable rack mount brackets. Mount at front panel or
mid-chassis location.

Weight

Approximately 33 lbs. (15 kg)

Approvals

CE-marked units meet IEC 1010-1 safety standard and
EN50081-2 and EN50082-1 EMC standards. Additional
standards: CSA C22.2 No. 1010.1, UL 3101, and FCC,
part 15, class A EMI standard.

Advertising