Installation, Introduction, Basic setup procedure – American Magnetics 12200PS DC Power Supply (CE-Marked) User Manual

Page 16: Inspection, cleaning, and packaging, Initial inspection, 1 initial inspection -1, Table 2.2-1 basic setup procedure -1, Installation 2.1 introduction, 2 basic setup procedure, 3 inspection, cleaning, and packaging

Advertising
background image

OPERATING MANUAL

INSTALLATION

Release 1.0 (98/07)

2-1

2. INSTALLATION

2.1 Introduction

This section provides recommendations and procedures for inspecting, installing, and testing the power supply.
Refer to the front and rear panel diagrams, Figure 2.3-1 and Figure 2.3-2, as necessary.

2.2 Basic Setup Procedure

Table 2.2-1 provides both a summary of the basic setup procedure and an overall view of the subsections in
Section 2. Use the procedure as a quick reference if you are familiar with the installation requirements for the
power supply. If you want more information, each step in the procedure refers to subsequent sections which
contain more details. Execute each step in the sequence given.

Table 2.2-1 Basic Setup Procedure

Step #

Description

Action

Reference

1

Inspection

Perform an initial physical inspection of
the supply.

Section 2.3 Inspection, Cleaning, and
Packaging

2

Installation

Install the supply (bench or rack mount),
ensuring adequate ventilation.

Section 2.4 Location, Mounting, and
Ventilation

3

Input Power

Connect AC input power.

Section 2.5 AC Input Power Connection

4

Test

Perform functional tests for voltage mode
operation, current mode operation, and
front panel controls.

Section 2.6 Functional Tests

5

Load

Connect the load.

Section 2.7 Load Connection

6

Sensing

Connect sensing lines.

Section 2.8 Local and Remote Sensing

See Section 3. Local Operation for instructions for front panel operation, over voltage and over temperature
protection, shutdown, and using multiple supplies. You will find remote programming and monitoring described
in Section 4. Remote Operation.

2.3 Inspection, Cleaning, and Packaging

2.3.1

Initial Inspection

When you first receive your unit, perform a quick physical check.

1.

Inspect the unit for scratches and cracks, and for broken switches, connectors, and displays. See Figure
2.3-1 an
d Figure 2.3-2.

2.

Have the service technician check the printed circuit board and its components if you suspect internal
damage.

If the unit is damaged, save all packing materials and notify the carrier immediately. See packing instructions in
Section 2.3.3.

Advertising