8. 2.66" Commercial Tank Stiffener Instructions (Outside Stiffened)

PNEG-1859 2.66" Corrugation 135' Diameter Tank with 50 PSF Snow Roof

35

2.66'' Corrugation Commercial Stiffeners Splice Details

When installing bottom stiffeners, you may find that in some cases the stiffener with base plate attached
will not rest on the foundation (due to unlevel foundation, etc.). Shim plates have been furnished and
should be used to fill opening between base plate and concrete.

IMPORTANT: If shim plates are not used where required, the downward pressure of the stiffeners will not

be transferred directly to the foundation and bin failure could result.

Stiffener Color Code Chart

NOTE: Some colors are different than those used for sidewall sheets.

*NOTE: Only Orange on 1 ring stiffener.

Figure 8C

Stiffener Gauge

Color Code

Stiffener Gauge

Color Code

15

Red/Orange*

6

White

14

Green/Orange*

5

Fluorescent Green

13

Dark Blue

5+12

Gold/Black

12

Black

5+10

Gold/Light Blue

11

Pink

5+8

Gold/Yellow

10

Light Blue

5+5

Gold/Fluorescent Green

9

Purple

5E+5U

Ochre/Gold/White

8

Yellow

5E+5E

Ochre/Gold/White/Brown