Lower flange brace instructions – Grain Systems Bin Accessories PNEG-1859 User Manual

Page 60

Advertising
background image

9. 2.66" Commercial Tank Roof Instructions

60

PNEG-1859 2.66" Corrugation 135' Diameter Tank with 50 PSF Snow Roof

Lower Flange Brace Instructions

Refer to Figure 9M and

Figure 9N

. NOTE: The purlins and Z-collars are hidden for clarity reasons.

The lower flange brace consists of two (2) brace clips (CRP-6450) attached to the bottom of every roof
beam. The brace clips (CRP-6450) are attached using 1/2" x 1-1/2" bolts (S-3728) and 1/2" nut (S-3729).
(See detail - lower flange ring

in Figure 9H on Page 54

for attachment detail.) The support ring pipe

(CRP-6382) then slides through the support ring clips. There are a total of fifteen (15) support ring pipes
(CRP-6382). Each support ring pipe spans three (3) bays. The pipe should be started halfway between
two (2) roof beams and end in the middle of two (2) roof beams, three (3) bays over. Each pipe should
be tight against the next pipe. The final support pipe placed under the roof beam will have to be cut to fit.
At each splice, wind ring couplers (SWS-4212) should be assembled to hold the pipes together. Wind ring
couplers are assembled using six (6) 3/8" x 1-1/2" flange bolts (S-7928) and flange nut (S-9373).

Figure 9M

Figure 9N

See detail

in Figure 9N

.

Advertising