6. Measuring and Special Equipment Required

6.1. Nitrogen gas, large cylinder.

6.2. Regulator, single stage with CGA 580 fitting, nitrogen gas service with gauges. (Must regulate to

200 PSIG -

See Page 25

.)

6.3. Hose with fittings on each end, high pressure (rated for > 500 PSIG).

6.4. Gauge, pressure (0-300 PSIG) or equivalent digital electronic pressure transducer or pressure

transmitter with readout device.

6.5. Power cord 16/3 AWG or 14/3 AWG with 120 VAC 3 prong plug on one end, bare wires and wire nuts

for the other end. (This will be used to power the 3/4" normally closed ASCO liquid line solenoid valve
during leak testing in

Page 25

,

Step 7.4.6 on Page 26

.)

6.6. Leak test solution, industrial grade. (To detect nitrogen gas leaks.)

6.7. Pipe cutting and threading equipment for 2", 1-1/4" and 3/4" piping.

6.8. Pipe thread sealant, industrial grade with PTFE and/or teflon tape.