8. TD-VIP-01 Data Sheet Selection

30

PNEG-1798 Tower and T-Series Dryers Vaporizer

Vaporizer Pressure Leak Test Data

Step #

Information

Recorded Data

Initials/Date

7.4.1 on Page 25

Bushing installed to accept the 300 PSIG test gauge.

7.4.2 on Page 25

Regulator connected to nitrogen cylinder and handle or knob
turned fully CCW.

7.4.3 on Page 25

High pressure hose connected to the regulator.

7.4.4 on Page 25

Hose end connected to the 3/4" manual isolation valve input.

7.4.5 on Page 25

Hose ends tightened at regulator and manual valve.

7.4.6 on Page 26

Power cord available and ready to connect to the 3/4" ASCO
solenoid valve wires.

7.4.7 on Page 26

Power cord black wire connected to one of the ASCO red wires.

7.4.8 on Page 26

Power cord white wire connected to the remaining ASCO red wire.

7.4.9 on Page 26

Power cord green wire connected to the ASCO green wire.

7.4.10 on Page 26

Power cord 3 prong male end plugged in a live 120V receptacle.

7.4.11 on Page 26

Audible click or popping sound heard at 3/4" ASCO solenoid.

7.4.12 on Page 26

Regulator high pressure gauge pressure reading.

PSIG

7.4.13 on Page 26

3/4" Manual isolation valve ‘CLOSED’.

7.4.14 on Page 26

Regulator low pressure gauge pressure reading.

PSIG

7.4.15 on Page 26

No leaks between nitrogen cylinder and input of 3/4" manual valve.

7.4.16 on Page 27

Test gauge reading with 3/4" manual valve ‘CLOSED’.

PSIG

7.4.17 on Page 27

Test gauge reading with 3/4" manual valve ‘OPEN’.

PSIG

7.4.18 on Page 27

Number of leaks initially found before repairs.

Leaks

7.4.19 on Page 27

Leaks of

7.4.18 on Page 27

repaired (If applicable).

7.4.20 on Page 27

1. Regulator adjusted to test pressure.

2. 0 Minute test time.

1. ______ PSIG

2. ______ Time

7.4.21 on Page 27

3/4" Manual isolation valve ‘CLOSED’.

7.4.22 on Page 27

Nitrogen cylinder supply valve ‘CLOSED’.

7.4.23 on Page 27

Regulator vented and no pressure indicated on regulator gauges.

7.4.24 on Page 27

Test gauge pressure reading during this step.

PSIG

7.4.25 on Page 27

1. Test pressure of

Step 7.4.20 on Page 16

.

2. 3 Minute test time after time of

Step 7.4.20 on Page 16

.

1. ______ PSIG

2. ______ Time

7.4.26 on Page 27

‘As found’

beginning of

3 minutes

1. Regulator adjusted to test pressure.

2. 0 Minute test time.

1. ______ PSIG

2. ______ Time

7.4.26 on Page 27

‘As left’ end of

3 minutes

1. Regulator adjusted to test pressure.

2. 0 Minute test time.

1. ______ PSIG

2. ______ Time