15. Inverted “T” Foundation 4" Outside Stiffened (WCL Series) Commercial Tanks
PNEG-318 Concrete Foundation Recommendations for GSI Grain Bins
101
Diameter of Bin: 36'
Soil Bearing Capacity: 3000 PSF
Ring #
12
14
16
18
A
1'-0"
1'-0"
1'-0"
1'-0"
B
3'-9"
4'-10"
5'-10"
6'-9"
C
18'-10"
18'-10"
18'-10"
18'-10"
D
19'-11"
20'-4"
20'-9"
21'-3"
M
5 #4's
5 #4's
5 #4's
5 #4's
N
4 #5's
5 #5's
6 #5's
7 #5's
P
#5 @ 14" c/c
#5 @ 14" c/c
#5 @ 10" c/c
#6 @ 10" c/c
Rerod
#4 (ft.)
3900
3900
3900
3900
#5 (ft.)
900
1100
1500
900
#6 (ft.)
0
0
0
1000
#7 (ft.)
0
0
0
0
Cu. Yds.
Concrete
Footing
16
21
25
29
Wall
22
22
22
22
Floor
18
18
18
18
Total
56
61
65
69
Diameter of Bin: 42'
Soil Bearing Capacity: 3000 PSF
Ring #
12
14
16
18
A
1'-0"
1'-0"
1'-0"
1'-0"
B
4'-0"
5'-1"
6'-2"
7'-1"
C
21'-10"
21'-10"
21'-10"
21'-10"
D
23'-0"
23'-6"
24'-0"
24'-5"
M
5 #4's
6 #4's
6 #4's
6 #4's
N
4 #5's
5 #5's
6 #5's
7 #5's
P
#5 @ 14" c/c
#5 @ 14" c/c
#6 @ 13" c/c
#6 @ 8" c/c
Rerod
#4 (ft.)
4700
5000
5000
5000
#5 (ft.)
1100
1300
900
1000
#6 (ft.)
0
0
800
1400
#7 (ft.)
0
0
0
0
Cu. Yds.
Concrete
Footing
20
25
31
35
Wall
25
25
25
25
Floor
25
25
25
25
Total
70
75
81
85