Grain Systems Bin Accessories PNEG-318 User Manual

Page 107

Advertising
background image

15. Inverted “T” Foundation 4" Outside Stiffened (WCL Series) Commercial Tanks

PNEG-318 Concrete Foundation Recommendations for GSI Grain Bins

107

Diameter of Bin: 48'
Soil Bearing Capacity: 3500 PSF

Ring #

12

14

16

18

A

1'-0"

1'-0"

1'-0"

1'-0"

B

3'-6"

4'-6"

5'-7"

6'-6"

C

24'-10"

24'-10"

24'-10"

24'-10"

D

25'-10"

26'-3"

26'-9"

27'-2"

M

6 #4's

7 #4's

5 #5's

5 #5's

N

4 #5's

5 #5's

6 #5's

7 #5's

P

#5 @ 14" c/c

#5 @ 14" c/c

#5 @ 10" c/c

#6 @ 9" c/c

Rerod

#4 (ft.)

6000

6300

4100

4100

#5 (ft.)

1100

1400

3500

2700

#6 (ft.)

0

0

0

1300

#7 (ft.)

0

0

0

0

Cu. Yds.

Concrete

Footing

20

26

32

37

Wall

29

29

29

29

Floor

33

33

33

33

Total

82

88

94

99

Diameter of Bin: 60'
Soil Bearing Capacity: 3500 PSF

Ring #

12

14

16

18

A

1'-0"

1'-0"

1'-0"

1'-0"

B

3'-10"

4'-11"

6'-2"

7'-1"

C

30'-9"

30'-9"

30'-9"

30'-9"

D

32'-3"

31'-11"

32'-4"

33'-7"

M

5 #5's

6 #5's

7 #5's

5 #6's

N

4 #5's

5 #5's

6 #5's

8 #5's

P

#5 @ 14" c/c

#5 @ 14" c/c

#6 @ 11" c/c

#6 @ 7" c/c

Rerod

#4 (ft.)

5700

5900

5900

5900

#5 (ft.)

3300

4100

3900

1600

#6 (ft.)

0

0

1200

4200

#7 (ft.)

0

0

0

0

Cu. Yds.

Concrete

Footing

27

35

43

54

Wall

36

36

36

36

Floor

51

51

51

51

Total

114

122

130

141