Grain Systems Bin Accessories PNEG-318 User Manual
Page 106
![background image](/manuals/277559/106/background.png)
15. Inverted “T” Foundation 4" Outside Stiffened (WCL Series) Commercial Tanks
106
PNEG-318 Concrete Foundation Recommendations for GSI Grain Bins
Diameter of Bin: 36'
Soil Bearing Capacity: 3500 PSF
Ring #
12
14
16
18
A
1'-0"
1'-0"
1'-0"
1'-0"
B
3'-1"
4'-0"
4'-10"
5'-10"
C
18'-10"
18'-10"
18'-10"
18'-10"
D
19'-8"
20'-0"
20'-5"
20'-10"
M
5 #4's
5 #4's
5 #4's
5 #4's
N
3 #5's
4 #5's
5 #5's
6 #5's
P
#5 @ 14" c/c
#5 @ 14" c/c
#5 @ 10" c/c
#6 @ 12" c/c
Rerod
#4 (ft.)
3900
3900
3900
3900
#5 (ft.)
700
900
1100
800
#6 (ft.)
0
0
0
700
#7 (ft.)
0
0
0
0
Cu. Yds.
Concrete
Footing
14
17
21
25
Wall
22
22
22
22
Floor
18
18
18
18
Total
54
57
61
65
Diameter of Bin: 42'
Soil Bearing Capacity: 3500 PSF
Ring #
12
14
16
18
A
1'-0"
1'-0"
1'-0"
1'-0"
B
3'-4"
4'-3"
5'-3"
6'-2"
C
21'-10"
21'-10"
21'-10"
21'-10"
D
22'-9"
23'-2"
23'-7"
24'-0"
M
5 #4's
6 #4's
6 #4's
6 #4's
N
4 #5's
4 #5's
5 #5's
7 #5's
P
#5 @ 14" c/c
#5 @ 14" c/c
#5 @ 11" c/c
#6 @ 10" c/c
Rerod
#4 (ft.)
4700
5000
5000
5000
#5 (ft.)
1000
1100
1500
1000
#6 (ft.)
0
0
0
1000
Cu. Yds.
Concrete
Footing
17
21
26
31
Wall
25
25
25
25
Floor
25
25
25
25
Total
67
71
76
81