5. Frost Free Pad FCDL

28

PNEG-318 Concrete Foundation Recommendations for GSI Grain Bins

Frost Free Pad (FCDL Bins) (Continued)

(Refer to Figure 5A on Page 24.)

Diameter of Bin: 48'
Corrugation: 4.00"

Ring #

B

N

Outside

Radius

Sq. Ft. Mesh

6 x 6 - 6/6

Optional #4

18" x 18" Grid (ft.)

Length #6

Bar (ft.)

Total Cu. Yds.

Concrete

6

1 ft. 5 in.

2

24 ft. 8 in.

3400

2300

400

44

7, 8

2 ft. 3 in.

3

24 ft. 11 in.

3400

2300

800

49

9

3 ft. 3 in.

4

25 ft. 2 in.

3400

2300

1100

55

10, 11

4 ft. 5 in.

5

25 ft. 8 in.

3400

2300

1400

63

12, 13

5 ft. 1 in.

5

25 ft. 11 in.

3400

2300

1500

67

14

5 ft. 8 in.

6

26 ft. 2 in.

5400

2300

1700

72

Diameter of Bin: 54'
Corrugation: 4.00"

Ring #

B

N

Outside

Radius

Sq. Ft. Mesh

6 x 6 - 6/6

Optional #4

18" x 18" Grid (ft.)

Length #6

Bar (ft.)

Total Cu. Yds.

Concrete

6

1 ft. 5 in.

2

27 ft. 9 in.

4800

3300

400

56

7, 8

2 ft. 3 in.

3

28 ft. 1 in.

4800

3300

600

63

9, 10

3 ft. 3 in.

4

28 ft. 4 in.

4800

3300

700

69

11, 12

4 ft. 5 in.

4

28 ft. 7 in.

4800

3300

1400

75

13, 14

6 ft. 0 in.

6

29 ft. 2 in.

4800

3300

1900

87

Diameter of Bin: 60'
Corrugation: 4.00"

Ring #

B

N

Outside

Radius

Sq. Ft. Mesh

6 x 6 - 6/6

Optional #4

18" x 18" Grid (ft.)

Length #6

Bar (ft.)

Total Cu. Yds.

Concrete

6

1 ft. 6 in.

2

30 ft. 7 in.

5400

3600

400

65

7, 8

2 ft. 10 in.

3

31 ft. 3 in.

5400

3600

1100

77

9, 10

3 ft. 8 in.

4

31 ft. 7 in.

5400

3600

1400

82

11, 12

4 ft. 7 in.

5

31 ft. 9 in.

5400

3600

1700

91

13

6 ft. 1 in.

6

32 ft. 4 in.

5400

3600

2200

103